Common Part Print E-mail
Thursday, 17 March 2011 16:33

SAFETY OF RESERVOIRED HYDRAULIC UNITS OF GEORGIA

G. KHELIDZE, I. NONIEV, R. PATARAIA
(Georgia)

Breakthrough wave or flood developed in the tail water from water-retaining construction sites (dams, dykes, locks, etc.) take one of the most important places with their negative outcome in the list of anthropogenic disaster. Naturally the society is interested in the provision of safety to the system - “water-retaining construction of the reservoir” which requires complex conduct of legal, administration and engineering and technical measures. Engineering and technical aspects of the safety of the dams of hydraulic units of Georgia are reviewed in the paper. Classification of water-retaining constructions and reservoirs by sizes and potential of possible dangers is elaborated. Grading of main reservoired hydraulic units of Georgia according to this feature is run. Classification considering the quantity of the population that might be subject to the effect of possible accidents at the location of Georgian hydraulic units is provided. Terms of the inspection of technical conditions of the reservoired hydraulic units of Georgia depending on the potential of containing danger are suggested.



Last Updated on Friday, 24 June 2011 07:19
 